<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-18 09-23-31
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.90 MHz 3/5, 50 dBuV LOOP
Pilot RDS Phase Difference
7.0 kHz 16 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 69 kHz 2964 0,1012
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,2 dBr 6,30 dBr 7,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" LOOP " 6459 0 (No PTY) 1 0 1 1 --:--
RT
"Mire "
AF EON
92.9, 106.1, 106.2 MHz -
FM Scope Max at: 69 kHz MIN: 13 kHz % above 76 kHz: 0,1012 Acquired: 2024/12/18 9.22.27 Total samples: 2964 Equivalent time: 0:02:28 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 7,1 dBr MIN: 4,2 dBr AVE: 6,30 dBr % above 12,2 dBr: 0,0 Last value: 6,6 dBr (2024/12/18 9.22.27) 09.08 09.10 09.12 09.14 09.16 09.18 09.20 09.22 0 50 100 Dev. MAX [kHz] 0 2 4 6 8 Pm [dBr]